Multifocal Atrial Tachycardia

Multifocal Atrial Tachycardia EKG tracing

marker1
marker2






Caliper Time Interval: ___ seconds




RhythmIrregular
RateFast (> 100 bpm)
P WaveOften changing shape and size from beat to beat (at least three differing forms)
PR IntervalVariable
QRSNormal (0.06-0.10 sec)
NotesT wave is often distorted Also review wandering atrial pacemaker lesson


This website is intended for use by medical professionals for educational purposes only. For medical care, contact a healthcare provider. Copyright 2017 © Medical Training and Simulation LLC. All Rights Reserved.

This website is intended for use by medical professionals for educational purposes only. For medical care, contact a healthcare provider. Copyright 2017 © Medical Training and Simulation LLC. All Rights Reserved.