Junctional Escape Rhythm

EKG Reference
Junctional Escape Rhythm
RateSlow (40-60 bpm)
P WavePresent before, during (hidden) or after QRS, if visible it is inverted
PR IntervalNot measurable
QRSNormal (0.06-0.10 sec)

Junctional Escape Rhythm EKG Tracing